Electrical fault-finding: open circuits, short circuits and high resistance – Motor Vehicle Theory motor mechanics lesson
Lesson 103 of 131 in the Motor Vehicle Theory course (ages 16+)
UK version. UK spelling and words (tyre, petrol, bonnet) and UK rules such as the MOT. · US version
Find out how the three classic electrical faults – open circuits, short circuits and high resistance – show themselves, and how a technician reasons from meter readings to the cause.
- Time
- 50 minutes + 10 min homework
- Course
- Motor Vehicle Theory (ages 16+)
- You need
- Paper, a pencil and this page. No tools and no vehicle
- Marked
- Instantly, with explanations
Education and interest only. Classfern teaches motor mechanics as a school subject. It is not a training course or a qualification, and nothing here replaces an IMI or City & Guilds course, an apprenticeship or a qualified technician. Never work on a real vehicle without a qualified adult, the right protective equipment and safe equipment. High-voltage parts of electric and hybrid vehicles are for trained technicians only. Rules and values on this page are given as of November 2026. Always check the current official source (GOV.UK and the DVSA MOT inspection manual) before relying on them.
How to use this lesson
This lesson teaches reasoning with Ohm's law and voltage readings. Any measurements on a real vehicle belong in a supervised college workshop with a qualified teacher. Every answer is marked straight away with a worked explanation.
- Read what you will learn and the big ideas.
- Press Start the lesson below for the teaching, worked examples and practice (Getting started, On track or Challenge).
- Finish with the exit ticket and the talk question: “Intermittent faults that come and go are the hardest to find. What could a technician do to make an intermittent fault show itself, and why might the customer's description be so important?”
- Later: the homework, then the practice test.
Watch out for
- Thinking a continuity test proves a cable or joint is good. It shows a path exists, but a joint that passes a meter's tiny current may still drop volts under working current. Test voltage drop with the circuit working.
- Thinking a reading of 12 V at the earth side of a lamp means the lamp is fine and everything is working. With the lamp on, its earth side should be near 0 V. Full voltage there means no current is flowing: the earth path is open.
- Fitting a new fuse and calling the job done. A blown fuse is a symptom. The short circuit that caused it must be found, or the new fuse will blow too.
Hands-on: On paper, draw a lamp circuit with a battery, fuse, switch, lamp and earth. Mark six test points. For each of these faults – broken feed wire after the switch, blown bulb, broken earth wire, corroded earth adding 1 Ω – write the voltage you would expect at every test point with the switch on (take the lamp as 2.4 Ω and the battery as 12 V). Paper and calculator only; no work on a real vehicle.
What you will learn
- I can describe open circuits, short circuits and high-resistance faults and their typical symptoms.
- I can predict the voltage at points around a working and a faulty circuit.
- I can explain why voltage-drop readings with current flowing find high resistance that a continuity test can miss.
- I can use Ohm's law to calculate the effect of an unwanted resistance on a load.
Key words
- open circuit
- A break in the circuit, so no current can flow. The load does not work at all.
- short circuit
- An unintended low-resistance path, usually a feed wire touching the body (a short to earth), causing a very high current that blows the fuse.
- high resistance
- Unwanted resistance in a connection, cable or switch. Current still flows but is reduced, so the load works poorly.
- continuity test
- A check with the circuit unpowered that a path exists between two points. It can show an open circuit but may not reveal high resistance.
The big ideas
Electrical faults can seem mysterious, but nearly all of them are one of three kinds. In an open circuit the path is broken, so nothing works. In a short circuit current takes an unintended shortcut, usually to earth, and the fuse blows. In a high-resistance fault the path is still there but something – corrosion, a loose terminal, a burnt contact – is adding resistance, so the load works weakly or intermittently.
Each fault leaves a fingerprint in the voltages around the circuit. A technician uses the wiring diagram to know what the voltage should be at each point, takes readings with a meter, and compares the two. The difference shows where the fault is.
This lesson explains the reasoning, using Ohm's law and voltage drop. It is not a repair guide: measurements on vehicles are made by, or under the supervision of, a qualified person, and never on the high-voltage system of an electric or hybrid vehicle, which HSE says is for trained technicians only.
Read-through: the teaching steps
Know what normal looks like
Before hunting for a fault, the technician uses the wiring diagram to work out what should happen. In a simple working lamp circuit with the switch on:
- battery side of the fuse – about battery voltage;
- after the fuse and switch – about battery voltage (less a very small drop);
- across the lamp – almost all of the battery voltage;
- lamp earth side – almost 0 V.
Any reading far from these values is a clue.
A simple lighting circuit. On a car the metal body is the return path (earth). Open circuits
An open circuit stops all current. Because there is no current, there is no voltage drop anywhere except across the break itself.
- Before the break, every point reads full battery voltage.
- After the break, every point reads 0 V – unless the break is on the earth side, in which case everything up to the break reads battery voltage, even the earth side of the lamp.
So the place where the reading changes from full voltage to zero is the break. Common causes are a blown bulb, a broken wire, a corroded connector pin or a failed switch.
Short circuits
A short to earth gives current an easy path that bypasses the load. The current is huge, so the fuse blows – often at once. Then the circuit is dead, which can look like an open circuit.
Clues: the fuse blows again as soon as it is replaced, or when one particular switch is operated or a door is opened (pointing to a chafed wire that moves). A technician finds it by isolating sections of the circuit and checking which section still has a path to earth.
A short can also be to another feed wire, so a component works when it should not.
High resistance
A high-resistance fault acts like an extra resistor in series. By Ohm's law it:
- reduces the current, so the load works weakly – dim lamps, slow motors;
- takes some of the voltage, so the load gets less;
- makes heat at the bad joint, which can discolour or melt the connector.
It may come and go with temperature or vibration, giving intermittent faults. It can be on the feed side or the earth side.
Why voltage drop beats continuity
A continuity test is done with the circuit unpowered, using the meter's own tiny current. A joint with a few strands of wire left, or a lightly corroded terminal, can pass that tiny current and look fine.
Under real working current the same joint may drop several volts. That is why technicians check voltage drop with the circuit working: measure across each section (feed cable, switch, connector, earth path) and look for any section dropping more than the manufacturer's figure. The load should take nearly all the voltage; everything else should take very little.
A logical routine
Good fault-finding follows the same order every time:
- Confirm the fault and note exactly what does and does not work.
- Study the wiring diagram: what do the faulty items share (a fuse, a return connection, a connector)?
- Make easy checks first (fuse, bulb, connector visible condition).
- Measure, starting where the diagram suggests, and compare with expected values.
- Repair the cause, then check the whole system works.
This is the same logical routine used across the vehicle, covered in the fault-finding lessons.
The lesson, step by step
| Part | Time | How it is checked |
|---|---|---|
| Starter: warm up | 4 min | Marked by Classfern |
| Teaching and hands-on task | 15 min | Not assessed, self-checked |
| Worked examples and guided practice | 10 min | Marked by Classfern |
| Independent practice (three levels) | 16 min | Marked by Classfern |
| Exit ticket and talk question | 5 min | Marked by Classfern, self-checked |
Make my lesson plan Opens this lesson in the free Lesson Plan Maker, filled in and ready to change, print or save.
The lesson
It runs here on the page. No sign-up and no names – progress is kept only in this browser.
Homework
About 10 minutes: 6 questions and a one-line reflection, all marked instantly.
More practice
More Electrical and electronic systems lessons · Motor Vehicle Theory course · All motor mechanics practice tests · Motor Mechanics Department